INSTALLATION DIAGRAMS
8
−−−−
sec.1
DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams
INSTALLATION DIAGRAMS
DIAGRAM NOTES
0,75
Cross-section
area sq.mm
0,35
Distance m 100
1
20050
Provide two wires for switching
on the push-button panel light
bulbs. Use a power transformer
suitable to the number of light
bulbs. The system transformer is
sufficient for up to 2 bulbs
(max 6 W).
C1.002 - MINIMUM WIRE
CROSS-SECTION AREAS
0,8
circuit
1
50
Distance
0,5
- The indicated distance is between
door unit and most distant door phone.
- Lay the wires at a suitable distance
from power lines (as far away as
possible).
m
0,5
call circuit
0,5 1
1,6
200 300100
0,8
sq.mm
Door opening
C4.001 - MINIMUM WIRE
CROSS-SECTION AREAS
Voice and
sq.mm
1
10,8mm
m
0,20
Diameter
120
1,6
Distance
0,65
Cross-section
0,5
sq.mm
480300200
0,8
C4.012 - MINIMUM WIRE
CROSS-SECTION AREAS
area
C4.004 - Use auxiliary relay
Ref.788/21 or 788/52 for operating the
lock in systems with long lines to
avoid buzzing.
C4.006 - Sinthesi models only:
- Connected jumper ... to ...
C4.007 - Sinthesi models only:
See instruction booklet provided with
product for connecting terminals G/T,
~0 and ~12 between modules.
C4.008 - K-Steel models only:
all connections are made with
terminal boards.
The connection variant is:
S3
S1
2
~12
~0
LOCK
DOOR PHONE
Ref.788/52
Door Lock
DEVICE
FROM 9 OF
ELECTRIC
12~
POWER SUPPLY
Release
DOOR PHONES
RELAY
C4.003
C4.015 - Repeater door phone call input
connections.
C4.014 -
Check that the diode respects
the polarisation shown in the diagram.
Call repeater
Ref.1332/84
Mod.1131
Mod.Scaitel
Mod. Atlantico
“4+n”
wire
systems
CA CA 2 7
6616
“1+1”
wire
systems
Mod.1130
“4+n”
wire
systems
“1+1”
wire
systems
C1.004 - K-Steel models only:
Remove the jumper
a)... and ...
Use two wires for lighting the panel
name tags if not included in the diagram.
Use a separate transformer of suitable
power.
Transformer Ref.9000/230 is recommended
for up to 15W-
The system power unit is sufficient for
up to 6W.
Door phone
Ref.1132/1 T1 T2 T3 T4
Ref.1133/1 T1 T2 T3
Ref.1131/1 ABCD
Terminal equivalence:
K
C4.009 - Important:
Use cord pairs.