INSTALLATION DIAGRAMS
10
−−−−
sec.1
DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams
INSTALLATION DIAGRAMS
DIAGRAM NOTES
VX.002 - The power unit can power
up to 10 distributors. Use one
local power unit Ref. 789/2 for
each group of distributors (max.
20) after exceeding this limit.
VX.003 - MINIMUM WIRE
CROSS-SECTION AREAS
Provide two wires for switching on
the push-button panel light bulbs.
Use a separate transformer suitable
to the number of light bulbs.
(Transformer ref. 9000/230 is
recommended for up to 5 bulbs).
The system power unit is sufficient
for up to 2 bulbs.
VX.006 - See the instruction book
provided with the product for fitting
the accessory in the device.
VX.007 - The cross-section area of the
wires indicated with must be
double.
Distance
Normal
COAXIAL
CABLE
COAXIAL
CABLE
75 Ohm
m
Sq.mm
50 100 200 300
0,5 0,8 1 1,6
0,8 1 1,6 2,5
Use a normal coaxial wire
for distances up to 300 m
Add a video amplifier for
longer distances.
Wires
R1,R2,+TC
Wires
Sq.mm
VX.010 - No more than 20 monitors
should be connected to each column;
add video distributors to the
camera output or other device if
there are more devices.
VX.014 - Dusk switch or similar device
for switching lights on, where
relevant.
VX.012 - Relay Ref.788/5 or Ref.788/52
is needed to prevent that a video door
phone can be switched on while another
device is working and interrupt vision.
Connect the PS wire directly to the
monitor X1 terminals if the relay is
not fitted.
VX.011 - Close the coaxial wire on
the last monitor in the riser with
a 75 Ohm resistance between
terminals V4 and V5.
VX.013 - Connect the switch-off
circuit Ref. 5330/60 in the
push-button panel and connect wire SN
(brown) to the button common. Cut and
isolate wire 1 (red).
VX.0
01
- To use video distributor
output U5, remove the 75 Ohm resistor
fitted on the printed circuit or
remove jumper (if existing).
VX.016 -
MINIME WIRE CROSS SECTION AREAS
Distance
75 Ohm
m
mmq
300 400 700 1000
1,6 1,75 2,5 4
VX.008 - Connect the devices to a
filter and power line protection
device.
1
2
IN OUT
2
1
Ref.1332/85
2
1
Ref.1332/86
IN OUT
2
1
NL
N
L
FilterProtection
Neutral
Mains ~
Line ~
Earth
Phase
Utility
VX.015 - The power unit Ref.1090/850
can power up to 4 devices.
Use another power unit for each group
of 4 devices if the system exceed
this capacity.
Voice and
call wires
Use a normal coaxial wire
for distances up to 300 m
Add a video amplifier for
longer distances.
The video amplifier must be installed
near the monitor.
Two BNC connectors are required for
connecting the coax wire. Use a RG59
(75Ohm) coax for a maximum distance
of 300m.
Use video amplifier Ref.1840/250 with
RG11 wire for higher distances