sec.1
−−−−
9
INSTALLATION DIAGRAMS
DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams
INSTALLATION DIAGRAMS
DIAGRAM NOTES
R2
CA
Maximum
distance
0,50
m
0,35
2,5
Double
0,75
0,5 1,0
1,5
A,B
200
0,35
0,35
2,0
Wires
R1 Sq.mm
0,35
0,75
10050
V5.001 - Wire cross-section area
The diagrams indicate the distance
between the camera and most distant
video door phone unit.
Normal wires can be used for
distances up to 100 metres. For
higher distances (up to 200 metres)
the wires A and B must be doubled.
V5.004 - On the last distributor,
insert two 82 Ohm resistors (provided)
between terminals R1-A and R1-B.
Sq.mm
Sq.mm
Sq.mm
wires
V5.002 -
Use two wires for lighting the
panel name tags if not included in the
diagram.
Use a separate transformer of suitable
power.
Transformer Ref.9000/230 is recommended
for up to 15W-
The system power unit is sufficient for
up to 6W.
VD.002 - See the chapter "Demister
power" in the chosen product manual
for K-Steel camera modules only.
VD.007 = Floor call button.
C4.016 - Sinthesi models only:
The call forwarded LEDs on all panels
light up when a call is in progress
from any station.
C4.017 - Sinthesi models only:
The call forwarded LED of the secondary
station in the column to which the call
is directed lights up when a call from
the main panel is in progress.
C4.018 - K-Steel model door units only:
connect terminals ~0 and ~12 for name
tag lighting.
C4.023 -
Set the (TIME) trimmer on the
device to minimum time.
CU.009 - Provide two wires for
switching on the push-button panel
light bulbs.
Use a power transformer suitable toe
the number of light bulbs.
Use of transformer Ref. 9000/230 is
recommended for up to five bulbs
(max 15 W).
Video signal
mmq
1,50
Video signal
0,35
-
mmq
mmq
0,75
mmq
0,35
-
AI
1,50
~0
100
The diagrams indicate the distance
between the thecamera and
video door phone unit.
Normal wires can be used for
distances up to 100 metres. For
higher distances (up to 200 metres)
the wires A and B must be doubled.
double
wires
0,35
-
2,50
Power 18V=
C1-C2
Auto power-on
mmq
Wires
Wires
200
~12
Video power
From camera to video door phones
0,35
R1
Video power
m
Power 18V=
0,75
1,5
0,35
50
1,5
0,5
R2
2,50
0,75
+18
0,75
0,35
Function
mmq
100
0,35
0,35
0,5
0,35
V5.007 -
MINIMUM WIRE
CROSS-SECTION AREAS
-
Power 12V~
Call
0,75
mmq
m
From power unit to camera
Power 12V~
B
R1
mmq
1,50
0,35
50
mmq
mmq
-
A
0,5
Function
1,50
V5.011 - Connect the wire for switch-on
function. In this case, connect jumper
between terminals X2 and R3.
Comentarios a estos manuales