INSTALLATION DIAGRAMS
DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams
INSTALLATION DIAGRAMS
DIAGRAM NOTES
VX.018 - Connect the following
jumpers on the device:
a) ..... with .....
b) ..... with .....
c) ..... with .....
VX.023 - Terminal equivalence:
- RT (Sentry+)= RD (Atlantico).
VX.021 - Cut or remove the jumpers on
the device(s):
- ...-...
- ...-...
-...-...
VX.025
EXAMPLE OF POWER CONNECTION WITH
ATLANTICO VIDEO DOOR PHONES
R1 R2
R
75
RD
R1
V3
V5
V4
R2
R1
RD
V3
V5
V4
R2
VX.032 - MINIME WIRE CROSS
SECTION AREAS
The section area and the voltage cable
(12Vcc 12Vdc)lenght are in function
of the camera intake.
See the following table:
Camera
intake
max 300mA
VX.031 - On the device remove
the jumper P1 which short circuit
the diode 1N4700. In intercom system
there is not necessary connect the
diode.
Cross section
area(mmq)
0,75
1,5
2,5
4
Distance
(m)
Camera
intake
Cross section
area(mmq)
Distance
(m)
150
100
240
50
VX.033 - MINIME WIRE CROSS
SECTION AREAS
The section area and the voltage cable
(12Vcc 12Vdc)lenght are in function
of the camera intake.
See the following table:
max 500mA
1
2,5
4200
125
50
VU.002 - Follow the instructions
provided with the product for
fitting the camera.
2
1
50
0,50,5 1
200 300100
0,8
VX.034 -
MINIME WIRE CROSS SECTION AREAS
Distance m
mmq
Normal
wires
0,50,5 10,8mmq
Wires
R1, R2, +TC
Call and
button
common
wires
0,8 10,5 1,6mmq
Use a normal coaxial wire
for distances up to 300 m
Add a video amplifier for
longer distances.
Use two wires for lighting the panel
name tags if not included in the diagram.
Use a separate transformer of suitable
power.
Transformer ref. 9000/230 is recommended
for up to 15W-
The system power unit is sufficient for
up to 6W.
COAXIAL
CABLE
75 Ohm
VX.028 - For Ref. 5330/60 only: cut
and isolate wire 1 (red)
NOTE 1: The electrical lock is shown in the diagrams and
must have the following features:
12Vac - 15VA
NOTE 2: The number of devices shown by an X must be